Air Conditioner Fan Spinning but Not Cooling Capacitor

It is a big deal when the air conditioning goes out on a calorific summertime daytime, but there is atomic number 102 need to wait for help to come to you.  Many air conditioning malfunctions are not difficult to identify and repair.  The following test procedure will help you identify if the problem with your open-air social unit is the devotee motor, the capacitor, operating room the contactor.

Condenser-Fan-Motor

Troubleshooting the "outdoor air conditioner unit not lengthwise" starts with both easy commonsense steps:

  1. Spend a penny certain the thermostat is correct to sang-froid and the indoor unit is running (blowing gentle wind come out the way strain vents).
  2. Hear to the outdoor building block for the sound of the compressor jetting.
  3. If you get word the compressor spouting go to "section A" below. Note, compressors can run quietly.
  4. If you cannot hear the compressor running go to "incision B" below.

Section A; you can learn the a/c compressor running play and the fan motor is not turn.

Because the compressor is running you know there is 220 volts power to the outdoor unit and you have a go at it the contactor is doing its job of delivering that 220 volts to the compressor and to the motor.  The malfunction volition represent a bad capacitor and/or a bad motor. Capacitors can be tested with multi-meters that have the ability to read microfarads operating room you can bring your capacitance (and your motor) to your nearest U-FIX-IT store for a free work bench test.  If the capacitor tests good then your motorial is terrible.

Admonish – Capacitors tush store an electric charge (like a shelling).  The shock hazard is not-lethal, but it is no entertaining.   Check the 220 volt top executive is off and discharge the capacitor by shorting between capacitor terminals (with insulated screwdriver) in front removing the wires from the terminals.

Interesting facts

  1. A capacitance connected to some the compressor and the motor hind end fail on just the motor side.
  2. Bad a/c fan motors can sometimes be started by "spinning" the fan blade with a stick – it is still a bad centrifugal.

Purchase a Modern AC Motor

Contactor

Section B; you cannot hear the a/c compressor running and the fan centrifugal is not turning.  Your next troubleshooting step will be checking the 220 volt top executive because it is highly unlikely some the compressor and the fan motor would fail at the same sentence.  Failure of the contactor (see picture above) most often produces this symptom.  You can prove the contactor is the job by using a multi-meter or you can bring your contactor to your nearest U-Desexualise-IT store for a free bench test.

Examination the contactor on air conditioning out-of-door unit

  1. Exploitation a multi-meter, verify in that respect is 220 volts going into the contactor, but null volts upcoming out of the contactor (to the motive and compressor). If you  you induce 220 volts coming out (contactor is estimable) then check the capacitor or bring information technology in to U-Jam-IT for a free bench see to it.
  2. Check for 24 volts crossways the coil terminals. If no 24 volts cry U-FIX-IT for assist.
  3. Contactor is corked if multi-meter reads 220 volts going in, zero volts coming out, and 24 volts across the coil terminals.

Contactor voltage check top view

Caution: use care when measuring live voltages not to skin senses bare connections or short them to the cabinet or to separate terminals with the meter probes.

Purchase a New AC Contactor

Part Request

Have intercourse the depart you are looking for but can't find it? Let us uncovering it and let you get it on when we do.

More From Jim Plummer

Jim is an ex-U. S. Air Force pilot and a business school graduate of University of Texas at Austin. He has been in the appliance parts business since 1975.

Leave a Response

Air Conditioner Fan Spinning but Not Cooling Capacitor

Source: https://www.ufixit.com/news/home-air-conditioner-not-cooling/

Post a Comment

0 Comments